Release Notes
• Issue 5:
Description
When CMC rmware is downgraded to 1.36 from 2.00 or later while network share is congured, the Server Components Update page
gets corrupted.
Resolution
Clear the network conguration before downgrading to 1.36
Versions/Systems Aected
CMC Version 1.36 or earlier for Dell PowerEdge VRTX
• Issue 6:
Description
When pinned cache is present, the controller failover feature does not work.
Resolution
Address the pinned cache before controller failover is allowed.
Versions/Systems Aected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX.
• Issue 7:
Description
While VD re-build operation is in progress, if SPERC controller fail-over is triggered, active alert for degraded VD is not displayed on the
Chassis Overview page.
Resolution
None. An active alert along with the CMC Log is generated for degraded VD (VDR8) before the SPERC controller fail-over is triggered.
After the SPERC controller fail-over occurs, the Active Alert message for degraded VD on the chassis overview page is cleared, but
SPERC functionality is not impacted.
Versions/Systems Aected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX.
• Issue 8:
Description
MCM Inventory report has limited RAID and NIC details. There is a dierence in the RAID and NIC inventory details on the Server
Component Update page and the MCM inventory report.
Resolution
In the CMC GUI, refer to the Server Overview > Update > Server Component Update page, it is accurate and current.
Versions/Systems Aected
All CMC versions including CMC 3.00 for Dell EMC PowerEdge VRTX.
Known Issues
15