Users Guide

Table Of Contents
Status Message Actions
the SD feature card installed is the active CMC and not the
standby CMC.
The feature card inserted is valid and contains
the following feature(s) FlexAddress: bound.
No action required.
The feature card inserted is valid and contains
the following feature(s) FlexAddress: bound to
another chassis, svctag=ABC1234, SD card SN =
1122334455.
Remove the SD card; locate and install the SD card for the
current chassis.
The feature card inserted is valid and contains
the following feature(s) FlexAddress: not bound.
The feature card can be moved to another chassis or can be
reactivated on the current chassis. To reactivate on the current
chassis, enter racadm racreset until the CMC module
with the feature card installed becomes active.
Use the following RACADM command to display all activated features on the chassis:
racadm feature -s
The command returns the following status message:
Feature Name = FlexAddress
Date/time Activated = 05 Oct 2013 - 11:50:49
Feature installed from SD-card serial number = CN0H871T1374036T00MXA00
Feature Name = FlexAddressPlus
Date/time Activated = 05 Oct 2013 - 11:50:49
Feature installed from SD-card serial number = CN0H871T1374036T00MXA00
Feature Name = ExtendedStorage
Current Status = redundant, active
Date/time Activated = 05 Oct 2013 - 11:50:58
Feature installed from SD-card serial number = CN0H871T1374036T00MXA00
If there are no active features on the chassis, the command returns a message:
racadm feature -s
No features active on the chassis
Dell Feature Cards may contain more than one feature. After any feature included on a Dell Feature Card has been activated on a chassis,
any other features that may be included on that Dell Feature Card cannot be activated on a dierent chassis. In this case, the racadm
feature -s command displays the following message for the aected features:
ERROR: One or more features on the SD card are active on another chassis
For more information about the feature and featurecard commands, see the Chassis Management Controller for PowerEdge VRTX
RACADM Command Line Reference Guide
available at the support site.
Conguring FlexAddress
FlexAddress is an optional upgrade that allows server modules to replace the factory-assigned WWN/MAC address with a WWN/MAC
address provided by the chassis.
NOTE
: In this section, the term FlexAddress also indicates FlexAddress Plus.
164 Using FlexAddress and FlexAdress Plus