Users Guide

Table Of Contents
Enable RAID Controller — Enables the RAID controller. If the PERC is already disabled, then Enable Raid Controller
option is available in the drop-down menu.
Reset Conguration — Select this option to delete virtual drive and unassign all the hot spares attached to the controller.
However, this only removes the disks from the conguration and does not delete any data. NOTE: Reset Conguration does not
remove any foreign congurations. Use Clear Foreign Conguration to reset.
Export TTY Log — Select this option to export the TTY log on the local system. NOTE: The TTY Log collected from the controller
does not contain any data from the drives. However, it may contain data such as SAS addresses.
Enable Fault Tolerance — Select this option to enable the fault-tolerance mode of the external SPERC. This action also resets the
External Shared PERC 8 card.
Disable Fault Tolerance — Select this option to disable the fault-tolerance mode of the external SPERC. This action also resets
the External Shared PERC 8 card.
NOTE:
For a disabled PERC, none of the other options Reset Conguration, Export TTY Log, Discard Pinned Cache, and Disable
RAID Controller are available in the drop-down menu.
By default the two integrated shared storage adapters are detected with high availability mode.
You must enable Fault Tolerance mode on the external shared controller after it is cabled.
Enable Fault Tolerance and Disable Fault Tolerance are displayed only for the External Shared PERC 8 cards. The default
mode of the External Shared PERC 8 cards is the non-fault-tolerant mode.
NOTE: Enabling or disabling a peer controller initiates a chassis power cycle. The changes are reected only after the power
cycle is complete.
Enabling or Disabling RAID Controller Using RACADM
To enable a peer controller using RACADM, open a serial/Telnet/SSH text console to CMC, log in, and enter:
racadm raid enableperc:<AdapterFQDD>
To disable a peer controller, enter:
racadm raid disableperc:<AdapterFQDD>
NOTE
: For more information on this feature using the RACADM interface see the
RACADM Command Line Reference Guide for
iDRAC and CMC
.
Enabling or disabling fault tolerance of external RAID
controller using RACADM
To enable the fault tolerance:
racadm raid controllers: <FQDD of External Shared PERC8> -p HighAvailabilityMode ha
To disable the fault tolerance:
racadm raid set controllers: <FQDD of External Shared PERC8> -p HighAvailabilityMode None
Viewing Physical Disk Properties Using the CMC Web
Interface
Make sure that physical disks are installed on the chassis.
To view the properties of physical disk drives:
1 In the left pane, go to Chassis Overview > Storage > Physical Disks.
The Properties page is displayed.
2 To view properties of all the physical disk drives, under the Physical Disks section, click the .
198