Users Guide

Table Of Contents
NOTE: The rollup status of the enclosure turns critical when the EMM, PSU, or Fan is removed but the primary Status remains
unchanged. After the CMC or chassis is power cycled, the primary status also changes to critical.
Viewing Status and Attributes of Enclosure Using RACADM
To view the status of the enclosure, use racadm raid get enclosures —o —p Status command.
To view the attributes of the enclosure, use racadm raid get enclosures —o command.
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available
at dell.com/support/manuals.
Reporting up to two Enclosures per Connector
Each External Shared PERC 8 card supports up to two enclosures per connector. However, there are two dierent congurations with
dierent restrictions. In a single PERC (non-fault tolerant) conguration you can connect up to two enclosures per card. Because of
redundant cabling, a Fault Tolerant External Shared PERC 8 card solution supports up to two enclosures per fault tolerant pair.
If more than two enclosures are detected on any connector, a warning message is logged to the chassis log. This aects chassis health and
provides an active alert or chassis log entry.
Setting Asset Tag and Asset Name of the Enclosure
To identify the enclosures, set the asset name and asset tag of the enclosures.
NOTE
:
Error is displayed if you enter an invalid value.
Initially the value which is saved in the rmware is displayed.
You must have Chassis Conguration Privileges to set asset tag and asset name of the enclosure.
You can set Asset Tag and Asset Name only for external enclosures.
Setting Asset Tag and Asset Name of the Enclosure Using Web Interface
To set the asset tag and asset name of the enclosure, click Chassis OverviewStorageEnclosuresSetup. Type the Asset Tag and
Asset Name in the appropriate elds, and then click Apply. For more information, see the CMC Online Help.
Setting Asset Tag and Asset Name of the Enclosure Using RACADM
To set asset tag of the enclosure, use racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.
5-1 –p AssetTag <value> command.
To set asset name of the enclosure, use racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.
5-1 –p AssetName <value>
command.
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available
at dell.com/support/manuals.
206