Users Guide

Table Of Contents
To set the maximum warning threshold of temperature probe in the enclosure, use racadm raid set
tempprobes:TempSensor.Embedded.0:Enclosure.External.1-0:RAID.ChassisSlot.6-1 –p
MaximumWarningThreshold <value> command.
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available
at
dell.com/support/manuals.
Viewing Fan Status and attributes of the Enclosure
Fan status and attributes displays the status of the enclosure fan and contains a status value that is unique from the enclosure. You can
have up to two fans, and the enclosure rmware creates a status for each fan. You must have CMC Login privileges to view fan status.
NOTE: If a PSU is missing, the corresponding fan of the PSU displays a critical status.
Viewing Fan Status and attributes of the Enclosure Using Web Interface
To view the status and attributes of PSU:
Click Chassis OverviewStorageEnclosuresProperties. The Enclosure Page provides the health status and attributes for the fan
of the enclosure. Expand the external enclosure to view the status for the fan of the enclosure. For more information, see the CMC Online
Help.
Viewing Fan Status and attributes of the Enclosure Using RACADM
To view the status of fan, use racadm raid get fans -o -p Status command.
To view the attributes of fan, use racadm raid get fans -o command.
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available
at dell.com/support/manuals.
Viewing Enclosure Properties Using CMC Web
Interface
To view the enclosure properties:
1 In the left pane, click Chassis Overview > Storage > Enclosures > Properties.
2 On the Properties page, under the Enclosure section, click the to get a graphical view of the physical disk drives and their states,
summary of physical disk drive slots, and advanced properties.
208