Users Guide

Table Of Contents
Short the Password recovery header pins using jumper
Re-insert the CMC module to chassis, after the CMC is in online state, the default credential is active (User Name: root/ Password:
calvin)
Login to CMC using default credential and change the password
After the password is changed, remove CMC module and jumper from Password recovery header
Re-insert the CMC module to chassis, after the CMC is in online state, the new credential is active
Gathering Conguration Information, Chassis Status,
and Logs Using RACDUMP
The racdump subcommand provides a single command to get comprehensive chassis status, conguration state information, and the
historic event logs.
The racdump subcommand displays the following information:
General system/RAC information
CMC information
Chassis information
Session information
Sensor information
Firmware build information
Supported Interfaces
CLI RACADM
Remote RACADM
Telnet RACADM
racdump includes the following subsystems and aggregates the following RACADM commands. For more information about racdump,
see the RACADM Command Line Reference Guide for CMC in PowerEdge VRTX.
Table 42. Racadm commands for subsystems
Subsystem RACADM Command
General System/RAC information
getsysinfo
Session information
getssninfo
Sensor information
getsensorinfo
Switches information (IO Module)
getioinfo
Mezzanine card information (Daughter card)
getdcinfo
All modules information
getmodinfo
Power budget information
getpbinfo
KVM information
getkvminfo
NIC information (CMC module)
getniccfg
Redundancy information
getredundancymode
Trace log information
gettracelog
214 Troubleshooting and Recovery