Users Guide

Table Of Contents
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available
at dell.com/support/manuals.
Enabling or Disabling Default Password Warning
Message
You can enable or disable the display of the default password warning message. To do this, you must have Congure Users privilege.
Enabling or Disabling Default Password Warning Message
Using Web Interface
To enable or disable the display of the default password warning message after logging in to iDRAC:
1 Go to Chassis Controller > User Authentication > Local Users .
The Users page is displayed.
2 In the Default Password Warning section, select Enable, and then click Apply to enable the display of the Default Password Warning
page when you log in to CMC. Else, select Disable.
Alternatively, if this feature is enabled and you do not want to display the warning message for subsequent login operations, on the
Default Password Warning page, select the Do not show this warning again option, and then click Apply.
Enabling or Disabling Warning Message to Change Default
Login Password Using RACADM
To enable the display of the warning message to change the default login password using RACADM, use racadm config -g
cfgRacTuning -o cfgRacTuneDefCredentialWarningEnable<0> or <1> object. For more information, see the Chassis
Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals.
Use case scenarios
This section describes typical use cases and tasks that you can perform with Chassis Management Controller Version 3.0 for Dell
PowerEdge VRTX.
Conversion of External Shared PERC 8 card High Availability to
Non-High Availability Mode using Web Interface
Dell PowerEdge VRTX chassis must have 2 External Shared PERC 8 cards in PCI slot 5 and PCI slot 6 in HA mode.
Workow
1 Power down chassis. Disconnect all SAS cables from External Shared PERC 8 cards to MD12x0 enclosures.
2 Power Up chassis.
3 Login to CMC web interface and navigate to the Storage→ Controllers→ Troubleshooting and disable Fault tolerance from the
drop-down menu for External Shared PERC 8 card in slot 5, click Apply and select disable for slot 6, and then click Apply.
4 Resetting both the PERCs may take two minutes to reect in Non-HA mode.
5 Power down chassis and connect the enclosures in Non-HA Mode.
6 Power Up chassis.
48
Logging in to CMC