Users Guide

Table Of Contents
Field Description
Job Status Displays the job status of any operations that are scheduled on the server. The job status is continuously
updated dynamically. If a job completion with state completed is detected, then the rmware versions for the
components and devices on that server are automatically refreshed in case there has been a change of
rmware version on any of the components or devices. An information icon is also presented adjacent to the
current state, which provides additional information about the current job status. This information can be
viewed by clicking or pausing the mouse over the icon.
Update Click to select the component or device for rmware update on the server.
Viewing Firmware Inventory Using RACADM
To view rmware inventory using RACADM, use the getversion command:
racadm getversion -l [-m <module>] [-f <filter>]
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available
at dell.com/support/manuals.
Saving Chassis Inventory Report Using CMC Web
Interface
To save the chassis inventory report:
1 In the system tree, go to Server Overview, and then click Update > Server Component Update.
The Server Component Update page is displayed.
2 Click Save Inventory Report.
The Inventory.xml le is saved on an external system.
NOTE
: The Dell Repository Manager Application uses the
Inventory.xml
le as an input to create a repository of updates for
all the blades available in the chassis. This repository can be later exported to a network share. Update from Network Share
mode of rmware update uses this network share to update the components of all the servers. You must have CSIOR
enabled on the individual servers and save the chassis inventory report every time there is a change to the chassis hardware
and software conguration.
Conguring Network Share Using CMC Web Interface
To congure or edit the Network Share location or credentials:
1 In the CMC web interface, in the system tree, go to Server Overview and then click Network Share.
The Edit Network Share page is displayed.
NOTE
: When you have same folder for chassis, server, and boot identity prole, you may see performance issues if there is
more than 100 proles.
2 In the Network Share Settings section, congure the following settings as required:
Protocol
IP Address or Host Name
Share Name
Update folder
File Name (optional)
NOTE
: Entering the File Name is optional only when the default catalog le name is catalog.xml. If the catalog le name is
changed, then the new name must be entered in this eld.
62 Updating Firmware