Users Guide

Table Of Contents
Viewing Information and Health Status of Temperature
Sensors
To view the health status of the temperature sensors:
In the left pane, click Chassis Overview > Temperature Sensors.
The Temperature Sensors Status page displays the status and readings of the temperature probes on the entire chassis (chassis and
servers). For more information, see Online Help.
NOTE: The temperature probes value cannot be edited. Any change beyond the threshold generates an alert that causes
the fan speed to vary. For example, if the CMC ambient temperature probe exceeds the threshold, the speed of the fans on
the chassis increases.
Viewing Storage Capacity and Status of the Storage
Components
To view the capacity and fault-tolerant status of the storage components, do one of the following:
1 Go to Chassis Overview.
The Chassis Health page is displayed. The Storage capacity details, the Fault Tolerant Mode (Active/Passive), and Fault Tolerant
Status (Enabled) information is displayed on the right pane. This fault-tolerance information is displayed only if the fault tolerant
feature is enabled for the storage components.
The lower section of chassis graphics provides the left view of the chassis. Move the cursor over the storage component sub-graphic.
The text hint provides additional information about the storage component. Click the storage component subgraphic to view the
related information in the right pane.
2 Alternatively, in the left pane, click Chassis Overview > Storage > Properties > Status.
The Storage Overview page is displayed with the following information:
View the graphic summary of the physical disk drives installed in the chassis and their status.
View the summary of all the storage components with links to their respective pages.
View the used capacity and total capacity of the storage.
View controller information.
NOTE
: In case of a fault-tolerant controller, the name format is: Shared
<PERC number
> (Integrated <number>). For
example, the active controller is Shared PERC8 (Integrated 1) and the peer controller is Shared PERC8 (Integrated 2).
View recently-logged storage events.
NOTE
: For more information, see the
Online Help
.
Viewing Chassis Information and Monitoring Chassis and Component Health 79