Owner's Manual

I/O Fabric Management 391
Warning Indicates that warning alerts have been issued,
and corrective action must be taken. If
corrective actions are not taken, it could lead
to critical or severe failures that can affect the
integrity of the IOM.
Examples of conditions causing Warnings:
IOM fabric mismatch with the server's
mezzanine card fabric; invalid IOM
configuration, where the newly installed
IOM does not match the existing IOM on
the same group.
Severe Indicates that at least one Failure alert has
been issued. Severe status represents a system
failure on the IOM, and corrective action must
be taken immediately.
Examples of conditions causing Severe status:
Failure in IOM detected; IOM was removed.
NOTE: Any change in health is logged to both the hardware and CMC
log. For information on viewing logs, see "Viewing the Hardware Log"
on page 422 and "Viewing the CMC Log" on page 424.
Power Status Displays the power status of the IOM: On, Off, or N/A (Absent).
Service Tag Displays the service tag for the IOM. The service tag is a unique
identifier provided by Dell for support and maintenance.
Fabric Displays the type of fabric for the IOM: Gigabit Ethernet, 10GE
XAUI, 10GE KR, 10GE XAUI KR, FC 4 Gbps, FC 8 Gbps, SAS 3
Gbps, SAS 6 Gbps, Infiniband SDR, Infiniband DDR, Infiniband
QDR, PCIe Bypass Generation 1, PCIe Bypass Generation 2.
NOTE: Knowing the fabric types of the IOMs in your chassis is critical
in preventing IOM mismatches within the same group. For information
about I/O fabric, see "I/O Fabric Management" on page 383.
Table 11-2. I/O Module Health Status Information
(continued)
Item Description