CLI Guide

cfgChassisDefaultPowerCapUpperBoundBTU (Read Only)
Table 307. Details of cfgChassisDefaultPowerCapUpperBoundBTU
Description Indicates the maximum default value to which you can set the
power cap of a chassis.
Legal Values 17060 BTU/h
Default 17060 BTU/h
cfgChassisDefaultPowerCapLowerBound (Read Only)
Table 308. Details of cfgChassisDefaultPowerCapLowerBound
Description Indicates the minimum default value to which you can set the
power cap of a chassis.
Legal Values Zero Watt
Default Zero Watt
cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
Table 309. Details of cfgChassisDefaultPowerCapLowerBoundBTU
Description Indicates the minimum default value to which you can set the
power cap of a chassis.
Legal Values Zero Watt
Default Zero Watt
cfgChassisPowerCap (Read/Write)
Table 310. Details of cfgChassisPowerCap
Description Indicates the maximum power consumption limit (in Watt) for the
entire chassis. The command generates an error if server throttling
is necessary to achieve the power goal based on the value for this
setting.
Legal Values 2715 – 16685 Watt
Default 16685 Watt
cfgChassisPowerCapF (Read/Write)
Table 311. Details of cfgChassisPowerCapF
Description Indicates the maximum power consumption limit (in Watt) for the
entire chassis. Use cfgChassisPowerCapF when power
consumption is to be changed regardless of whether server
throttling is required. This command generates an error if the value
for this setting is lower than the minimum power required for the
chassis configuration.
160 CMC Property Database Group and Object Descriptions