• cmc.alert.audit.lic.critical
Input
• get - Displays the list of event filter settings.
• set - Configures the actions and notifications for a given event filter configuration.
• -c - Alert descriptor of the specific event filter.
• -n - The notification to be sent when the event occurs. Valid values are all, snmp, ipmi, lcd, email,
or none. You can append multiple notifications separated by a comma. You cannot enter the values
all or none with other notifications.
NOTE: If both event generation interval and notifications are configured and there is an
error while configuring the notifications, the event generation interval is not set. The
valid values are from 0–365. 0 disables the event generation.
Example
• Display all available event filter configurations:
racadm eventfilters get -c cmc.alert.all
• Display eventfilter configurations for a specific category. For example, audit:
racadm eventfilters get -c cmc.alert.audit
• Display eventfilter configurations for a specific subcategory. For example, licensing under the audit
category:
racadm eventfilters get -c cmc.alert.audit.lic
• Display eventfilter configurations for a specific severity. For example, warning under the audit
category:
racadm eventfilters get -c cmc.alert.audit.warning
• Display eventfilter configurations for a specific severity and subcategory. For example, a severity of
warning in the subcategory licensing under audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
• Clear all available alert settings:
racadm eventfilters set -c cmc.alert.all -n none
• Configure using severity as a parameter. For example, all informational events in storage category
are assigned poweroff as action, and email and snmp as notifications:
racadm eventfilters set -c cmc.alert.storage.info -n email,snmp
• Configure using subcategory as a parameter. For example, all configurations under the licensing
subcategory in the audit category are assigned poweroff as action and all notifications are enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all
• Configure using subcategory and severity as parameters. For example, all Information events under
the licensing subcategory in the audit category are assigned poweroff as action and all notifications
are disabled:
racadm eventfilters set -c cmc.alert.audit.lic.info -n none
fanoffset
Table 17. Details of fanoffset
Description
Configures the internal fans to run at a higher speed than the normal speed.
To use this subcommand, you must have the Chassis Configuration Administrator privilege.
RACADM Subcommand Details 31