CLI Guide

cmc-2
3.00.000.201609223282 Y
<Chassis Infrastructure> <FW Version> <FQDD>
Main Board 2.21.A00.201510302495
System.Chassis.1#Infrastructure.1
<Storage Controller> <FW Version> <FQDD>
Shared PERC8
23.13.06.0011 RAID.ChassisIntegrated.1-1
<Storage Enclosure> <FW Version> <FQDD>
VRTX2.5x25 0:0 1.02
Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
<Physical Disk> <FW Version> <FQDD>
Physical Disk 0:0:0 AS09
Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:1 AS09
Disk.Bay.1:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:10 AS09
Disk.Bay.10:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:11 AS09
Disk.Bay.11:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:12 AS09
Disk.Bay.12:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:13 AS09
Disk.Bay.13:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:14 AS09
Disk.Bay.14:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:18 AS09
Disk.Bay.18:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:19 AS09
Disk.Bay.19:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:2 AS09
Disk.Bay.2:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:3 AS09
Disk.Bay.3:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:4 AS09
Disk.Bay.4:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:5 AS09
Disk.Bay.5:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:6 AS09
Disk.Bay.6:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:7 AS09
Disk.Bay.7:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:8 AS09
Disk.Bay.8:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:9 AS09
Disk.Bay.9:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
-b - Displays the server's current BIOS version (default is iDRAC version).
-c - Displays the server's current CPLD version.
-l - Displays the firmware versions Lifecycle Controller components.
-f <filter> - Filters the components. Must be used with -1 and be one of the following values:
bios: BIOS
idrac: iDRAC
usc: Unified Server Configurator (Lifecycle Controller)
diag: 32-bit Diagnostics
drivers: OS Driver Package
nic-x: Network Interface card. See -l output for possible values of x.
raid-x: RIAD Controller. See -l output for possible values of x.
-m <module> - Specifies the module or device for which you must retrieve the version information.
<module> is one of the following:
RACADM Subcommand Details