CLI Guide

Example
racadm raid exportlog:RAID.ChassisIntegrated.1-1 -l <CIFS or NFS share> -
u<username> -p <password> [-f <filename>]
forceonline
Table 90. Details of forceonline
Description
Forces the RAID Controller to make the specified drive online. This operation may result in obsolete or corrupted
data, and should only be attempted in cases where a rebuild operation has failed or is not applicable.
Synopsis
racadm raid forceonline:<PD FQDD> {current|pending}
Input
–current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, then the system is rebooted.
–pending: Save the configuration change for a later application. You can use a combination of the –pending and
–current flags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid
forceonline:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
get controllers
Table 91. Details of get controllers
Description The command lists all RAID controllers detected in the system and their properties.
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
raid get controllers -o
Input -o — The -o is used to display the fault-tolerant status of a RAID controller.
Example Sample output of a CMC in which either fault-tolerant mode is not available or is not enabled.
RAID.ChassisIntegrated.1-1
Status = Ok
RollupStatus = Ok
Name = Shared PERC8 (Embedded)
FirmwareVersion = 23.8.3-0027
DriverVersion = 06.802.11.00
RebuildRate = 30 %
BgiRate = 35 %
CheckConsistencyRate = 40 %
ReconstructRate = 30 %
PatrolReadRate = 30 %
PatrolReadMode = Manual
PatrolReadState = Stopped
CheckConsistencyMode = Stop On Error
LoadBalanceSetting = Disabled
CopybackMode = OFF
PreservedCache = Not Present
CacheMemorySize = 1024 MB
PersistHotspare = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare = Disabled
Timeintervalforspindown = 30 (Minutes)
SecurityStatus = Unknown
EncryptionMode = None
RACADM Subcommand Details 79