CLI Guide

CheckConsistencyRate = 40 %
ReconstructRate = 30 %
PatrolReadRate = 30 %
PatrolReadMode = Manual
PatrolReadState = Stopped
CheckConsistencyMode = Stop On Error
LoadBalanceSetting = Disabled
CopybackMode = OFF
PreservedCache = Not Present
CacheMemorySize = 1024 MB
PersistHotspare = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare = Disabled
Timeintervalforspindown = 30 (Minutes)
SecurityStatus = Unknown
EncryptionMode = None
SasAddress = 0x590B11C02620E600
PciDeviceId = 0x2f
PciSubdeviceId = 0x1f3e
PciVendorId = 0x1000
PciSubvendorId = 0x1028
PciBus = 0x0
PciDevice = 0x0
PciFunction = 0x0
BusWidth = Unknown
SlotLength = Short
SlotType = Unknown
CapableSpeeds = 6.0 Gb/s, 3.0 Gb/s
LearnMode = Not supported
HighAvailabilityMode = Fault Tolerant(Active/Passive)
PeerController =
RAID.ChassisIntegrated.1-1
get enclosure
Table 92. Details of get enclosure
Description Displays the status and attributes of the enclosure.
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm raid get enclosures -o -p Status
racadm raid get enclosures -o
Input -o — The -o is used to display the fault-tolerant status of a enclosure.
-p — The network password of the share.
Example
racadm raid get enclosures -o -p Status
Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
Status = Ok
Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Failed
racadm raid get enclosures -o
Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
Status = Ok
RollupStatus = Ok
Name = VRTX2.5x25 0:0
BayId = 0
RACADM Subcommand Details 81