CLI Guide

Input -o — The -o is used to display the fault-tolerant status of a enclosure.
Example
racadm raid get psus -o -p Status
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
racadm raid get psus -o
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 0
PartNumber = 0NFCG1A01
PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 1
PartNumber = 0NFCG1A01
PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 0
PartNumber = 0D1YWRA00
PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 1
PartNumber = 0GV5NHA00
get tempprobes
Table 96. Details of get tempprobes
Description Displays the status and attributes of the temperature sensors in the storage enclosure that are connected to
chassis
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm raid get tempprobes -o -p Status
racadm raid get tempprobes -o
Input -o — The -o is used to display the fault-tolerant status of a enclosure.
Example
racadm raid get tempprobes -o -p Status
TempSensor.Embedded.2:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
TempSensor.Embedded.3:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
TempSensor.Embedded.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
TempSensor.Embedded.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
TempSensor.Embedded.2:Enclosure.External.0-0:RAID.ChassisSlot.5-1
RACADM Subcommand Details 85