CLI Guide

init
Table 102. Details of init
Description
Starts an initialization operation on the specified virtual drive.
Synopsis
racadm raid init:<VD FQDD> -speed {fast | full} {-current | -pending}
Input
–current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot it will reboot then.
–pending: Save the configuration change for a later application. You can use a combination of the –pending and
–current flags on multiple commands to reduce the possible number of system reboots.
–speed{fast | full}: Perform a fast or full (slow) initialization on the virtual drive.
Example
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed fast
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed full
raid
Table 103. Details of raid
Description Monitors, retrieves inventory, and configures the storage components connected to the chassis.
NOTE: To use this subcommand, you must have the Chassis Administrator privilege.
Synopsis
racadm raid get status
racadm raid get <Object type>
racadm raid get <Object type> -o
racadm raid get <Object type> -o -p <property names separated by comma>
racadm raid get <Object type>:<FQDD's of Object type separated by comma>
racadm raid set <Set Operation>:<FQDD of Object type>
racadm raid set <Set Operation> -pdkey:<FQDD of PD>
racadm raid set <Set Operation> -vdkey:<FQDD of VD>
Input
NOTE:
Maximum property names that can be specified in –p option is 10.
Maximum FQDDs that can be specified is 3.
(Object type) — controllers, vdisks, pdisks.
Set Operation
resetconfig
exportlog
forceonline
deletevd
blink
RACADM Subcommand Details 89