1. In the left pane, click Chassis Overview > Storage > Properties > Storage Overview.
2. On the Storage Overview page, you can:
View the graphic summary of the physical disk drives installed in the chassis and their status.
View the summary of all the storage components with links to their respective pages.
View the used capacity and total capacity of the storage.
View controller information.
NOTE: In case of a fault-tolerant controller, the name format is: Shared <
PERC number
> (Integrated <number>).
For example, the active controller is Shared PERC8 (Integrated 1) and the peer controller is Shared PERC8
(Integrated 2).
NOTE: If the secondary PERC is disabled, the name is displayed as Disabled PERC (Integrated 2).
View recently-logged storage events.
NOTE: For more information, see the
Online Help
.
Viewing the Storage Topology
To view the Storage topology:
1. In the left pane, click Chassis Overview > Storage > Properties > Topology.
2. On the Topology page, click the <controller name> to view the respective pages.
NOTE: You can view the name of the controller that is active in controlling the storage devices associated with this
CMC and also the passive controller acting as a stand-by.
3. Under each installed controllers, click the links View Virtual Disks, <enclosure name>, and View Physical Disks to open the
respective pages.
Viewing Fault-tolerant Troubleshooting
Information of SPERC Using CMC Web Interface
To view the attributes that indicate the correct functioning of fault-tolerant features of a SPERC:
1. In the left pane, click Chassis Overview > Storage > Troubleshooting > Setup Troubleshooting.
The Storage Setup Troubleshooting page is displayed.
2. On the Storage Setup Troubleshooting page, you can:
Click to view the following attributes when the integrated controller is in fault-tolerant mode:
Two Shared PERCs detected.
Two expanders detected
Shared PERCs and expanders correctly cabled
Correct Firmware on Shared PERCs
Correct Firmware on Expanders
Correct Firmware on Chassis Infrastructure
Shared PERCs have the same settings: Indicates whether or not SPERCs have the same settings.
Click
to view the following attributes when the integrated controller is not in fault-tolerant mode:
One Shared PERC detected
One expanders detected
Shared PERC and expanders correctly cabled
Click to view the following attributes when the external controller is in fault tolerant:
Two Shared PERCs detected
Shared PERCs are installed in different fabrics
Shared PERCs and EMMs are connected correctly
Correct firmware on Shared PERCs
Shared PERCs have the same settings
Click to view the following attributes when the external controller is not in fault-tolerant mode:
Managing Chassis Storage