Users Guide

The Log in Security page is displayed.
3. To enable the user blocking or IP blocking feature, in the Login Lockout Policy section, select Lockout by User Name or Lockout
by IP Address (IPV4) .
The options to set the other login lockout policy attributes are activated.
4. Enter the required values for login lockout policy attributes in the activated fields — Lockout Fail Count, Lockout Fail Window ,
and Lockout Penalty Time. For more information, see the CMC Online Help.
5. To save these settings, click Apply.
Configuring Login Lockout Policy Attributes Using
RACADM
You can use RACADM to configure the Login lockout policy attributes for the following features:
User blocking
IP address blocking
Number of login attempts allowed
Timespan for the lockout failure counts to occur
Lockout penalty time
To enable user blocking feature, use:
racadm config -g cfgRacTuning -o cfgRacTuneUserBlkEnable <0|1>
To enable IP blocking feature, use:
racadm config –g cfgRacTuning –o cfgRacTuneIPBlkEnable <0|1>
To specify the number of login attempts, use:
racadm config –g cfgRacTuning –o cfgRacTuneIpBlkFailCount
To specify the time span within which, lockout fail count failures must occur, use:
racadm config –g cfgRacTuning –o cfgRacTuneIpBlkFailWindow
To specify value for lockout penalty time, use:
racadm config –g cfgRacTuning –o cfgRacTuneIpBlkPenaltyTime
For more information about these objects, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line
Reference Guide available at dell.com/support/manuals.
Understanding Redundant CMC Environment
You can install a standby CMC that takes over if your active CMC stops functioning. The redundant CMC may be pre-installed or can be
installed later. To make sure full redundancy or best performance, it is important that the CMC network is properly cabled.
Failovers can occur when you:
Run the RACADM cmcchangeover command. See the cmcchangeover command section in the Chassis Management Controller
for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals.
Run the RACADM racreset command on the active CMC. See the racreset command section in the Chassis Management
Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals..
Reset the active CMC from web interface. See the Reset CMC option for Power Control Operations that is described in Executing
Power Control Operations.
Remove the network cable from the active CMC.
Remove the active CMC from the chassis.
Initiate a CMC firmware flash on the active CMC.
Have an active CMC that is no longer functional.
NOTE:
In the event of a CMC failover, all iDRAC connections and all active CMC sessions are logged off. Users with
logged-off sessions must reconnect to the new active CMC.
Installing and Setting Up CMC 35