Users Guide

cfgRemoteHosts
cfgSerial
cfgSessionManagement
For more information about the property default values and ranges, see the Chassis Management Controller for PowerEdge VRTX
RACADM Command Line Reference Guide available at dell.com/support/manuals.
Configuring iDRAC Virtual LAN Tag Settings
Virtual LAN (VLAN) tags enable multiple VLANs to coexist on the same physical network cable and to segregate the network traffic for
security or load management purposes. When you enable the VLAN functionality, each network packet is assigned a VLAN tag. VLAN tags
are chassis properties. They remain with the chassis even when a component is removed.
NOTE: The VLAN ID configured using CMC is applied to iDRAC only when iDRAC is in dedicated mode. If iDRAC is in
shared LOM mode, the VLAN ID changes made in iDRAC are not displayed on the CMC GUI.
Configuring iDRAC Virtual LAN Tag Settings Using
RACADM
Specify the Virtual LAN ID and priority of a particular server with the following command:
racadm setniccfg -m server-<n> -v <VLAN id> <VLAN priority>
The valid values for <n> are 1–4.
The valid values for <VLAN> are 1–4000 and 4021–4094. Default is 1.
The valid values for <VLAN priority> are 0–7. Default is 0.
For example:
racadm setniccfg -m server-1 -v 1 7
For example:
To remove a server VLAN, disable the VLAN capabilities of the specified server's network:
racadm setniccfg -m server-<n> -v
The valid values for <n> are 1–4.
For example:
racadm setniccfg -m server-1 -v
Configuring iDRAC Virtual LAN Tag Settings Using Web
Interface
To configure Vitual LAN(VLAN) for server:
1. Go to any of the following pages:
In the left pane, click Chassis Overview > Network > VLAN.
In the left pane, click Chassis Overview > Server Overview and click Setup > VLAN.
2. On the VLAN Tag Settings page, in the iDRAC section, enable VLAN for the server(s), set the priority and enter the ID. For more
information about the fields, see the Online Help.
3. Click Apply to save the settings.
94
Configuring Servers