CLI Guide

Table 115. Details of serveraction (continued)
Turn off the server from iDRAC when Power is already off on that server.
racadm serveraction powerdown
Server is already powered OFF
Get Power Status of server 2 on CMC
racadm serveraction -m server-2 powerstatus
ON
Get Power Status on iDRAC
racadm serveraction powerstatus
Server Power Status: ON
Reseat server 2 on CMC
$ racadm serveraction -m server-2 reseat -f
Server power operation successful
Explanation of Support
iDRAC needs to support graceful shutdown
The support of address individual blades is expected on the CMC
set
Table 116. Details of set
Description
Import saved CMC or server configuration or CMC Event Filter configuration from a file.
NOTE: If CMC is not in the network, you cannot import the chassis configuration profile
from a remote network share with proxy using the set command. But, you can import the
chassis configuration profile from the local management station.