CLI Guide

Table 120. Details of setflexaddr (continued)
racadm setflexaddr -f A 1
Fabric A FlexAddress state set successfully
racadm setflexaddr -f idrac 1
setled
Table 121. Details of setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator privilege on
CMC. To enable the servers to blink or unblink, you must have the Server Administrator or Debug
Administrator privilege on CMC.
Synopsis
racadm setled -m <module> -l <ledState>
Input -m <module> - Specifies the module whose LED you want to configure.
<module> can be one of the following:
— server-n, where n=1–4
— switch-n, where n=1
— cmc-active
— chassis
-l <ledstate> - Specifies whether the LED should blink.
<ledstate> can be one of the following:
– 0 — no blinking
– 1 — blinking
Example
racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a multi-slot
server.
racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
set enclosure
Table 122. Details of set enclosure
Description Sets the asset tag and asset name of the enclosures.
NOTE: Set enclosure is used for the storage expansion feature when available with shared
external PERCs.
NOTE: You cannot modify the asset names for internal enclosures.
RACADM Subcommand Details 105