cfgRacTuneTelnetPort (Read/Write)
Table 223. Details of cfgRacTuneTelnetPort
Description Specifies the port number used for iDRAC or CMC Telnet
interface.
NOTE: For CMC, the following port numbers are
reserved and cannot be used: 21, 68, 69, 111, 123, 161,
546, 801, 4096, 5988, 5989, 6900, 9000, and 60106.
Legal Values For iDRAC: 1 – 65535
For CMC: 10 – 65535
Default 23
cfgRacTuneDaylightOffset (Read Only)
Table 224. Details of cfgRacTuneDaylightOffset
Description Specifies the daylight savings offset (in minutes) to use for the RAC Time. This value is 0 if the time zone is
not a Daylight Saving time zone.
Legal Values 0 – 60
Default 0
cfgRacTuneTimezoneOffset (Read Only)
Table 225. Details of cfgRacTuneTimezoneOffset
Description Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT)/Coordinated Universal Time (UTC)
to use for the RAC Time. Some common time zone offsets for time zones in the United States are:
–480 (PST—Pacific Standard Time)
–420 (MST—Mountain Standard Time)
–360 (CST—Central Standard Time)
–300 (EST—Eastern Standard Time)
For CMC: This object property is read only. Specifies the difference in number of seconds, from the UTC/GMT.
This value is negative if the current time zone is west of Greenwich.
Legal Values –720 to 7800
Default 0
cfgRacTuneWebserverEnable (Read/Write)
Table 226. Details of cfgRacTuneWebserverEnable
Description Enables or disables the Web server. If this property is disabled,
CMC is not accessible using client Web browsers. This property
has no effect on the Telnet/SSH or RACADM interfaces.
Legal Values 1 (TRUE)
0 (FALSE)