CLI Guide

Table 29. Example
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present PCIe OK PCIe OK
server-2 Not Present None N/A None N/A
server-3 Present PCIe OK None N/A
server-4 Not Present None N/A None N/A
Table 30. getdcinfo
<Server#> <Presence> <DC1 Model Name> <DC2 Model Name>
server-1 Present None None
server-2 Not Present None None
server-3 Not Present None None
server-4 Present None Broadcom M5708t
getflexaddr
Table 31. Details of getflexaddr
Description Enabled or disabled status is displayed for the entire chassis and
fabric ID decoder. Use the command with -i option to display the
MACs/WWN on a per-slot-basis
The decoder values in the Type column indicate the protocols of
the network cards:
0— Unsupported
1— ISCSI
2— FCoE-FIP
3— iSCSI/FCoE-FIP
To use this subcommand, you must have CMC Login User
privilege.
NOTE: If FlexAddress is not activated on the chassis,
the command displays server-assigned MAC/WWN
addresses. If the slot is empty, the command leaves the
server-assigned MAC/WWN addresses blank. If an
external console controls the MAC/WWN addresses, the
command displays an externally managed message.
42 RACADM Subcommand Details