CLI Guide

Table 33. FlexAddress setting (continued)
10 GbE KR/3 00:90:FA:51:36:56 F8:DB:88:3D:A2:78(act
ive)
NOTE: 10 GbE KR/3— The value 3 indicates the protocol type.
getioinfo
Table 34. getioinfo
Description Displays general information about the I/O modules on the chassis.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fiber Channel,
and Infiniband.
Synopsis
racadm getioinfo
racadm getioinfo [-m <module>]
racadm getioinfo [-m <module>][-s]
Input -m — Specifies the module or device. The <module> must be switch — <n>, where n = 1–2
-s — Displays the stack information.
Table 35. Example
<IO> <Power> <Name> <Role> <Mode> <Type> <Presenc
e>
<POST>
switch-1 ON R1-PT
VRTX
1Gb
Master
Pass-
through
N/A Gigabit
Ethernet
Present OK
getled
Table 36. Details of getled
Description Displays the LED settings on a module: blinking, not blinking, or
unknown (for empty slots).
To use this subcommand, you must have the Login User privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m <module> — Specifies the module whose LED settings you
want to view.
<module> can be one of the following:
server-n where n=1–4
switch-n where n=1
44 RACADM Subcommand Details