CLI Guide

Table 72. getversion (continued)
Synopsis
racadm getversion
racadm getversion [-b | -c] [-m <module>]
racadm getversion -l [-m <module>] [-f <filter>]
Input
NOTE: The -b, -c and -l options are not available for CMC modules.
NOTE: The -l option requires that the Lifecycle Controller service is enabled on the servers. For
version information, see the RACADM Readme available at dell.com/support/manuals.
(none) — Displays the version information for all targets or devices.
<Server> <iDRAC Version> <Blade Type> <Gen>
<Updatable>
server-3 2.20.20.20 (41) PowerEdge M630
(VRTX) iDRAC8 Y
<Switch> <Model Name> <HW Version> <FW
Version>
switch-1 R1-PT VRTX 1Gb Pass-through
A00 1.0.0.8
<CMC> <CMC Version> <Updatable>
cmc-1 3.00.000.201609223282 Y
cmc-2
3.00.000.201609223282 Y
<Chassis Infrastructure> <FW Version> <FQDD>
Main Board 2.21.A00.201510302495
System.Chassis.1#Infrastructure.1
<Storage Controller> <FW Version> <FQDD>
Shared PERC8
23.13.06.0011 RAID.ChassisIntegrated.1-1
<Storage Enclosure> <FW Version> <FQDD>
VRTX2.5x25 0:0 1.02
Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
<Physical Disk> <FW Version> <FQDD>
Physical Disk 0:0:0 AS09
Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:1 AS09
Disk.Bay.1:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:10 AS09
Disk.Bay.10:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:11 AS09
Disk.Bay.11:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:12 AS09
Disk.Bay.12:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:13 AS09
Disk.Bay.13:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:14 AS09
Disk.Bay.14:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:18 AS09
Disk.Bay.18:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:19 AS09
Disk.Bay.19:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:2 AS09
Disk.Bay.2:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:3 AS09
Disk.Bay.3:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:4 AS09
66
RACADM Subcommand Details