CLI Guide

Table 93. Details of get emms (continued)
PartNumber = 0W307KA00
FirmwareVersion = 1.05
get fans
Table 94. Details of get fans
Description Displays the status and attributes of the fans in the storage enclosure that are connected to chassis.
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm raid get fans -o -p Status
racadm raid get fans -o
Input -o — The -o is used to display the fault-tolerant status of a enclosure.
Example
racadm raid get fans -o -p Status
Fan.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.2:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.3:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.2:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.3:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
racadm raid get fans -o
Fan.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 0
Speed = 4620 RPMS
Fan.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 1
Speed = 4620 RPMS
Fan.Slot.2:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 2
Speed = 4490 RPMS
Fan.Slot.3:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 3
Speed = 4560 RPMS
Fan.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 0
RACADM Subcommand Details
87