CLI Guide

Table 103. Details of raid (continued)
Example
racadm raid get controllers
racadm raid get controllers -o
racadm raid get controllers -o -p name,status
racadm raid get vdisks -o -p layout,status
racadm raid get controllers:RAID.ChassisIntegrated.1-1
racadm raid get controllers:RAID.ChassisIntegrated.1-1 -p status
racadm raid resetconfig:RAID.ChassisIntegrated.1-1
racadm raid exportlog:RAID.ChassisIntegrated.1-1 -l <CIFS or NFS share>
-u <user name> -p <password> [-f <filename>]
racadm raid
forceonline:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-
1
racadm raid deletevd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid blink:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid clearconfig:RAID.ChassisIntegrated.1-1
racadm raid importconfig:RAID.ChassisIntegrated.1-1
racadm raid ccheck:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid cancelcheck:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 {-
pdkey:<comma separated PD FQDDs> | {-vdkey:<comma separated VD FQDDs>}
racadm raid ccheckall:RAID.ChassisIntegrated.1-1
racadm raid cancelcheckall:RAID.ChassisIntegrated.1-1
racadm raid unblink {-pdkey:<comma separated PD FQDDs> | -vdkey:<comma
separated VD FQDDs>}
racadm raid patrolread:RAID.ChassisIntegrated.1-1 [-mode {auto | manual
| disabled}] [-state {start | stop}] racadm raid
hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1 -
assign {yes | no} -type { ghs | dhs} -vdkey:<FQDD of VD>
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed
{ fast | full } racadm raid
cancelinit:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 racadm raid
assignva:<VA FQDD> -vdkey:<FQDD of VD> -accesspolicy { na | rw }
racadm raid cancelinit:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid assignva:<VA FQDD> -vdkey:<FQDD of VD> -accesspolicy { na |
rw } -assignpolicy {single|multiple}
racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl {r0|r1|r5|r6|r10|
r50|r60} [-wp {wt|wb|fwb}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|16k|
32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}] -pdkey:<comma separated PD
FQDD> [-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD
size>{b|k|m|g|t}] [-cc] [-sc {span count}] {-current|-pending} [-vdinit
{yes|no}] [-secure {yes|no}]
[-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD size>
{b|k|m|g|t}] [-cc]
racadm raid discardcache:RAID.ChassisIntegrated.1-1
racadm raid changepolicy:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -wp
{wt|wb} -rp {nra|ra|ara} -dcp {enabled|disabled|default} racadm raid
rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD name>
racadm raid rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD
name>
racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-rebuild <value>>] [-
bgi <value>] [-reconstruct <value>] [-checkconsistency <value>] [-
ccmode {abortonerror | normal}] [-copybackmode {off | on |
onwithsmart}] [-lb {auto | disabled}] [-prunconfigured {yes | no}]
racadm raid
rebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
94