CLI Guide

enableperc
Table 106. Details of enableperc
Description
Indicates the RAID configuration of hardware RAID connected to the server. This subcommand enables the power
to a RAID card.
NOTE:
Using this subcommand will power cycle the chassis and set the fault-tolerant system
configuration to fault-tolerant mode.
If any PERC adapter settings are changed or firmware is updated, a message is displayed and
the fault-tolerant status is degraded. Make sure that the firmware and the settings of the
SHARED PERC match to set the fault-tolerant system configuration to fault-tolerant mode.
Synopsis
racadm raid enableperc:<AdapterFQDD>
Example
racadm raid enableperc:RAID.ChassisIntegrated.2-1
disableperc
Table 107. Details of disableperc
Description
Indicates the RAID configuration of hardware RAID connected to the system. This subcommand disables the
power to a RAID card.
NOTE:
Using this subcommand power cycles the chassis and sets the fault-tolerant system
configuration to Single PERC mode.
Synopsis
racadm raid disableperc:<ControllerFQDD>
Example
racadm raid disableperc:RAID.ChassisIntegrated.2-1
createsecuritykey
Table 108. Details of createsecuritykey
Description
Assigns a security key to the controller.
Synopsis
racadm raid createsecuritykey:<ControllerFQDD> -key <Key id> -passwd
<passphrase>
Input
-key <Key id> — key id. The key identifier can be a minimum of one character and maximum of 32 characters.
It must not have spaces.
-passwd <passphrase> — passphrase. The passphrase can be a minimum of eight characters and a
maximum of 32 characters. The passphrase must have one character from each of the following:
uppercase
lowercase
number
non-alphanumeric character except space
96 RACADM Subcommand Details