Users Guide

Table Of Contents
Supported Interfaces
CLI RACADM
Remote RACADM
Telnet RACADM
racdump includes the following subsystems and aggregates the following RACADM commands. For more information about racdump,
see the RACADM Command Line Reference Guide for CMC in PowerEdge VRTX.
Table 43. Racadm commands for subsystems
Subsystem RACADM Command
General System/RAC information
getsysinfo
Session information
getssninfo
Sensor information
getsensorinfo
Switches information (IO Module)
getioinfo
Mezzanine card information (Daughter card)
getdcinfo
All modules information
getmodinfo
Power budget information
getpbinfo
KVM information
getkvminfo
NIC information (CMC module)
getniccfg
Redundancy information
getredundancymode
Trace log information
gettracelog
RAC event log
getraclog
System event log
getsel
Downloading SNMP Management Information Base File
The CMC SNMP Management Information Base (MIB) file defines the chassis types, events, and indicators. CMC enables you to
download the MIB file using the web interface.
To download the CMC's SNMP MIB file using the CMC web interface:
1. In the left pane, click Chassis Overview > Network > Services > SNMP.
2. In the SNMP Configuration section, click Save to download the CMC MIB file to your local system.
For more information about the SNMP MIB file, see the Dell OpenManage Server Administrator SNMP Reference Guide at dell.com/
support/manuals.
First Steps to Troubleshoot a Remote System
The following questions are commonly used to troubleshoot high-level issues in the managed system:
Is the system turned on or turned off?
If turned on, is the operating system functioning, not responding, or stopped functioning?
If turned off, did the power turn off unexpectedly?
Power Troubleshooting
The following information helps you to troubleshoot power supply and power-related issues:
Problem: Configured the Power Redundancy Policy to Grid Redundancy, and a Power Supply Redundancy Lost event was
raised.
196
Troubleshooting and Recovery