Users Guide

Table Of Contents
Front Panel LCD Messages
This section contains two subsections that list error and status information that is displayed on the front panel LCD.
Error messages on the LCD have a format that is similar to the System Event Log (SEL) viewed from the CLI or Web interface.
The tables in the error section list the error and warning messages that are displayed on the various LCD screens and the possible cause
of the message. Text enclosed in angled brackets (< >) indicates that the text may vary.
Status information on the LCD includes descriptive information about the modules in the chassis. The tables in this section describe the
information that is displayed for each component.
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front panel LCD for each type of component in the chassis.
Table 46. CMC Status
Item Description
Name/Location Example: CMC1, CMC2.
No Errors If there are no errors, No Errors is displayed. Else, error messages are listed
where critical ones are first listed, and then the warning-related.
Firmware Version Only displays on an active CMC. Displays Standby for the standby CMC.
IP4 <enabled, disabled> Displays current IPv4 enabled state only on an active CMC.
IP4 Address: <address, acquiring> Only displays if IPv4 is enabled only on an active CMC.
IP6 <enabled, disabled> Displays current IPv6 enabled state only on an active CMC.
IP6 Local Address: <address> Only displays if IPv6 is enabled only on an active CMC.
MAC: <address> Displays the CMC's MAC address.
Table 47. Chassis or Enclosure Status
Item Description
User Define Name Example: “Dell Rack System”. This can be configured using the CMC CLI or Web interface.
Error Messages If there are no errors, No Errors is displayed. Else, error messages are listed where critical ones are
first listed, and then the warning-related.
Model Number Example "PowerEdgeM1000".
Power Consumption Current power consumption in watts.
Peak Power Peak power consumed in watts.
Minimum Power Minimum power consumed in watts.
Ambient Temperature Current ambient temperature in degrees Celsius.
Service Tag The factory-assigned service tag.
CMC redundancy mode Non-Redundant or Redundant.
PSU redundancy mode Non-Redundant, Grid Redundant, or DC Redundant.
Table 48. Fan Status
Item Description
Name/Location Example: Fan1, Fan2, and so on.
Error Messages If there are no errors, No Errors is displayed. Else, error messages are listed where critical ones are first listed, and
then the warning-related.
208 Using LCD Panel Interface