Users Guide

Table Of Contents
Table 17. Server Module Inventory Field Descriptions (continued)
Data Field Example
NOTE: Requires VRTX CMC 1.0 (or later) on member; otherwise shown as blank.
Data Format
The inventory report is generated in a .CSV file format such that it can be imported to various tools, such as Microsoft Excel. The
inventory report .CSV file can be imported into the template by selecting the Data > From Text in MS Excel. After the inventory report
is imported into MS Excel, and if a message is displayed asking you for additional information, select comma-delimited to import the file
into MS Excel.
Chassis Group Inventory and Firmware Version
The Chassis Group Firmware Version page displays the group inventory and firmware versions of the servers and the server
components in the chassis. This page also enables you to organize the inventory information and filter the firmware versions view. The
displayed view is based on the servers or any of the following chassis server components:
BIOS
iDRAC
CPLD
USC
Diagnostics
OS Drivers
RAID
NIC
NOTE:
The inventory information displayed for the chassis group, member chassis, servers, and server components is
updated every time a chassis is added or removed from the group.
Viewing Chassis Group Inventory
To view the chassis group using CMC web interface, in the left pane, select Group. Click Properties > Firmware Version. The Chassis
Group Firmware Version page displays all the chassis in the group.
Viewing Selected Chassis Inventory Using Web Interface
To view the selected chassis inventory using CMC Web interface:
1. In the system tree, select Group. click Properties > Firmware Version.
The Chassis Group Firmware Version page displays all the chassis in the group.
2. In the Select a Chassis section, select the member chassis for which you want to view the inventory.
The Firmware View Filter section displays the server inventory for the selected chassis and the firmware versions of all the server
components.
Viewing Selected Server Component Firmware Versions
Using Web Interface
To view the firmware versions of selected server components using CMC web interface:
1. In the left pane, select Group. Click Properties > Firmware Version.
The Chassis Group Firmware Version page displays all the chassis in the group.
2. In the Select a Chassis section, select the member chassis for which you want to view the inventory.
3. In the Firmware View Filter section, select Components.
4. In the Components list, select the required component- BIOS, iDRAC, CPLD, USC, Diagnostics, OS Drive, RAID devices (up to 2),
and NIC devices (up to 6), for which you want to view the firmware version.
The firmware versions of the selected component for all the servers in the selected member chassis are displayed.
Configuring CMC
85