Quick Reference Guide

cfgUserAdminSolEnable (Read/Write)
Description Enables or disables Serial Over LAN (SOL) user access for
the user.
This object property is specific to iDRAC.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
cfgUserAdminIpmiSerialPrivilege (Read/Write)
Description The maximum privilege on the IPMI LAN channel.
This object is applicable only for iDRAC on Rack and
Tower Servers and not for iDRAC Enterprise on Blade
Servers or CMC.
Legal Values
2 (User)
3 (Operator)
4 (Administrator)
15 (No access)
Default
4 (User 2)
15 (All others)
cfgEmailAlert
This group contains parameters to configure iDRAC or CMC e-mail alerting capabilities. Up to four instances of this
group are allowed.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privileges.
NOTE: For CMC, you can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option.
The following sections provide information about the objects in the cfgEmailAlert group.
cfgEmailAlertIndex (Read Only)
Description The unique index of an alert instance.
Legal Values 1-4
Default <
instance
>
127