Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
Subcommand CMC
Telnet/SSH/Serial Remote RACADM
getioinfo Yes Yes
getkvminfo Yes Yes
getled Yes Yes
getmacaddress Yes Yes
getmodinfo Yes Yes
getniccfg Yes Yes
getpbinfo Yes Yes
getpminfo Yes Yes
getraclog Yes Yes
getractime Yes Yes
getredundancymode Yes Yes
getsel Yes Yes
getsensorinfo Yes Yes
getslotname Yes Yes
getssninfo Yes Yes
getsvctag Yes Yes
getsysinfo Yes Yes
gettracelog Yes Yes
getversion Yes Yes
help and help subcommand Yes Yes
ifconfig Yes Yes
krbkeytabupload No Yes
netstat Yes Yes
ping Yes Yes
ping6 Yes Yes
racdump Yes Yes
racreset Yes Yes
racresetcfg Yes Yes
remoteimage Yes Yes
set Yes Yes
serveraction Yes Yes
setarraycfg Yes Yes
setassettag Yes Yes
setchassisname Yes Yes
setflexaddr Yes Yes
setled Yes Yes
setniccfg Yes Yes
10 Introduction