Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
cfgOobSnmpAgentEnable (Read or Write)
Description
Enables or disables the SNMP agent in CMC.
Legal Values
● 1 (TRUE)
● 0 (FALSE)
Default
0
cfgOobSnmpProtocol
Description
Specifies the SNMP protocol used for SNMP traps.
Legal Values
● 0 — All
● 1 — SNMPv3
Default
0
cfgOobSnmpTrapFormat
Description
Specifies the format for SNMP traps.
Legal Values
● 0 — SNMPv1
● 1 — SNMPv2
● 2 — SNMPv3
Default
0
cfgTraps
This group displays information for and configures delivery of SNMP traps for a specific user.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
NOTE:
You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable
object, use the —o option.
cfgTrapsIndex (Read Only)
Description
Indicates the unique index of an alert instance.
Legal Values
1–4
Default
1
cfgTrapsEnable (Read or Write)
Description
Enables or disables event traps on the CMC.
Legal Values
● 1 (TRUE)
CMC Property Database Group and Object Descriptions 115