Reference Guide

Table Of Contents
Example
racadm getconfig -g cfgCurrentLanNetworking
# cfgNicCurrentIPv4Enabled=1
# cfgNicCurrentIpAddress=143.166.152.116
# cfgNicCurrentNetmask=255.255.255.0
# cfgNicCurrentGateway=143.166.152.1
# cfgNicCurrentDhcpWasUsed=0
# cfgNicCurrentVlanEnable=0
# cfgNicCurrentVlanID=1
# cfgNicCurrentVlanPriority=0
# cfgDNSCurrentServer1=192.168.0.5
# cfgDNSCurrentServer2=192.168.0.6
# cfgDNSCurrentDomainName=MYDOMAIN
cfgCurrentIPv6LanNetworking (Read Only)
This group displays the current CMC IPv6 properties.
Use this object with the getconfig subcommand.
To use this object property, you must have the CMC Login User privilege.
cfgCurrentIPv6Enabled (Read or Write)
Description
Indicates whether IPv6 is enabled on the CMC. If the current property value is set to 0 (false), the remote
network interfaces to the CMC are not accessible over IPv6.
Legal Values
0 Disabled
1 Enabled
Default
0
cfgCurrentIPv6AutoConfigWasUsed (Read or Write)
Description
Indicates whether auto configuration is used to obtain IPv6 settings, including stateless IPv6 addresses and
gateway.
Legal Values
0 (static addressing is used)
1 (address is obtained from the DHCPv6 server and/or stateless auto configuration)
Default
None
cfgCurrentLinkLocalAddress (Read Only)
Description
Displays the current IPv6 link-local address of the CMC.
Legal Values
None
Default
None
150 CMC Property Database Group and Object Descriptions