Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
16 Enabled Not Present
<Fabric> <Type> <Status>
A Gigabit Ethernet Enabled
B None Enabled
C None Enabled
Display the current flexaddress setting for slot 9.
racadm getflexaddr -i 9
Slot-9 server presence = Present
Slot-9 flexaddress enabled = 1
<Fabric> <Type> <Server-Assigned> <Chassis-Assigned>
slot9-idrac Controller 18:A9:9B:FD:C1:C9 F8:BC:12:E5:FE:98(a
ctive)
slot9-A1 10 GbE KR 00:90:FA:51:2E:22 F8:BC:12:E5:FE:99(a
ctive)
10 GbE KR/3 00:90:FA:51:2E:23 F8:BC:12:E5:FE:9B(a
ctive)
FCoE-WWN 10:00:00:90:FA:51:2
E:23
20:01:F8:BC:12:E5:F
E:9B(active)
slot9-A2 10 GbE KR 00:90:FA:51:2E:2A F8:BC:12:E5:FE:9A(a
ctive)
slot9-B1 Gigabit Ethernet A0:36:9F:12:3D:38 F8:BC:12:E5:FE:9D(a
ctive)
NOTE:
10 GbE KR/3— The value 3 indicates that the fabric is iSCSI/FCoE-FIP.
getfanreqinfo
Description
Displays fan speed request for servers and switches in percent (%).
To run this subcommand, you must have the CMC Login User privilege.
42 RACADM Subcommand Details