Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
10 GbE KR/3 Present 00:90:FA:51:3
4:F5
Unknown Factory
Switch-6 10 GbE KR Present
00:00:00:00:0
0:00
N/A Factory
getmodinfo
Description Displays configuration and status information for all modules or a specified module (server, switch, CMC,
fan unit, power supply unit (PSU), KVM, or I2C cable) in the chassis.
A power state of "Primary" denotes Active CMC.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The Service tag field is blank for modules that do not have service tag.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
● -m <module> — Specifies the module whose configuration and status information you want to view.
The default command (no options) displays information about all major components in the chassis.
<module> may be any of the following values:
○ server-<n> where n=1–16
○ server-<nx> where n=1–8; x = a, b, c, d
○ switch-<n> where n=1–6
○ cmc-<n> where n=1–2
○ fan-<n> where n=1–9
○ ps-<n> where n=1–6
○ chassis
○ kvm
○ io-cable
○ fpc-cable
● -A — Suppresses headers or labels in the output.
Examples
Display status of all the modules in the chassis
racadm getmodinfo
Display status of fan module 3 in the chassis
racadm getmodinfo -m fan-3
● racadm getmodinfo -m switch-1
<
module>
<presence> <pwrState> <health> <svcTag> <nodeId>
Switch-1 Present ON OK 0000000 N/A
● racadm getmodinfo
<
module>
<presence> <pwrState> <health> <svcTag> <nodeId>
54 RACADM Subcommand Details