Reference Guide

Display eventlter congurations for a specic severity and subcategory. For example, a
severity of warning in the subcategory licensing under audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
Clear all available alert settings:
racadm eventfilters set -c cmc.alert.all -n none
Congure using severity as a parameter. For example, all informational events in storage
category are assigned powero as action, and email and snmp as notications:
racadm eventfilters set -c cmc.alert.storage.info -n email,snmp
Congure using subcategory as a parameter. For example, all congurations under the licensing
subcategory in the audit category are assigned powero as action and all notications are
enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all
Congure using subcategory and severity as parameters. For example, all Information events
under the licensing subcategory in the audit category are assigned powero as action and all
notications are disabled:
racadm eventfilters set -c cmc.alert.audit.lic.info -n none
feature
Description Displays all active chassis features. The information displayed includes feature name, date activated and the
serial number of the SD card used to activate the feature.
Dell Feature Cards may contain more than a feature. After any feature included on a Dell Feature Card is
activated on a chassis, any other features that may be included on that Dell Feature Card cannot be activated
on a dierent chassis.
NOTE: To use this subcommand to deactivate FlexAddress, you must have the Chassis Conguration
Administrator privilege. A user with login privileges can view status only.
NOTE: To deactivate FlexAddress features, the chassis must be turned o.
Synopsis
racadm feature -s
racadm feature -d -c <featurename>
racadm feature -r -c ExtendedStorage
Input
-s
–Displays the status of active features.
-d
–Deactivates feature specied in -c option.
NOTE: When the FlexAddress and FlexAddressPlus feature are active, deactivating one of them
results in deactivation of the other feature also.
-1
—Congures extended storage feature for standalone use.
-2
—Congures extended storage feature for redundant use.
-r
—Reformats damaged or unformatted extended storage media.
CAUTION: Using the -r switch deactivates the extended storage feature, if active; reformats the SD
card in the active CMC card slot; and may Restart the active CMC.
-c
24