Reference Guide
• Group Name
• Group IP
• Fabric Selection
<module> conguration completed successfully.
Example
• Get the congured storage array properties from server–3.
racadm getarraycfg -m server-3
• Query for current storage conguration process status on server–3.
racadm getarraycfg -m server-3 -s
getassettag
Description Displays the asset tag for the chassis.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getassettag [-m <module>]
Input -m <module> — Species the module whose asset tag you want to view.
Legal value: chassis
Example
• Display asset tag for chassis
racadm getassettag -m chassis
• racadm getassettag
chassis 78373839–33
getchassisname
Description
Displays the name of the chassis.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getchassisname
Input N/A
Example
racadm getchassisname
CMC-JGB6B2S
getcong
Description
Displays CMC conguration properties.
Synopsis
• racadm getconfig -g <group> [-m <module>]
• racadm getconfig -g <group> -o <object> [-m <module>]
• racadm getconfig -g <group> -i <index>
• racadm getconfig -g <group> -o <object> -i <index>
• racadm getconfig -u <username>
•
racadm getconfig -h
32