Reference Guide

NIC Selection =dedicated
Link Detected =Yes
Speed =1Gb/s
Duplex Mode =Full Duplex
Active NIC =Dedicated
Static IPv4 settings:
Static IP Address =192.168.0.120
Static Subnet Mask =255.255.255.0
Static Gateway =192.168.0.1
Static IPv6 settings:
Static IP Address 1 =2000:de11:bcd1:fc14:1234:5678:2468:abcd/64
Static Prefix Length =64
Static Gateway =::
NOTE: IPv6 information is displayed only if IPv6 is enabled in iDRAC.
NOTE: IPv6 Address 1 eld indicates static IP and IPv6 Address 2 eld indicates dynamic IP.
Example
Display CMC network settings
racadm getniccfg -m chassis
getpbinfo
Description
Displays power budget status information.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getpbinfo
Input N/A
Example
Displays power budget status information
racadm getpbinfo
[Power Budget Status]
System Input Power = 1574 W
Peak System Power = 1916 W
Peak System Power Timestamp = 09:29:20 11/26/2014
Minimum System Power = 374 W
Minimum System Power Timestamp = 09:20:51 11/26/2014
Overall Power Health = OK
Redundancy = No
System Input Power Cap = 16685 W
Redundancy Policy = None