Reference Guide
setexaddr
Description Enables or disables FlexAddress on a particular slot or fabric.
To run this subcommand, you must have the Chassis Conguration Administrator privilege.
If the fabric type is determined to be InniBand, the operation is canceled and the command returns an error. If
the FlexAddress feature is not activated, the command returns an error.
NOTE: The server must be turned o to change the slot state. All servers must be turned o to
change the fabric state. The MAC/WWN addresses must be managed locally (not by an external
console) to run this command.
Synopsis
• racadm setflexaddr -i <slotNum> 0|1
• racadm setflexaddr -f <fabricName> 0|1
Input
• -i <slotNum> — Enables or disables FlexAddress for the specied slot.
• -f <fabricName> — Enables or disables FlexAddress for the specied fabric.
• <slotNum>= 1–16
• <fabricName>= A, B, C, iDRAC
– 0 : Disable
– 1 : Enable
Example
• Disable exaddress for slot 2.
racadm setflexaddr -i 2 0
• Enable exaddress for fabric A.
racadm setflexaddr -f A 1
• Disable exaddress for fabric B.
racadm setflexaddr -f b 0
• Disable exaddress for fabric iDRAC.
racadm setflexaddr -f idrac 0
setled
Description
Sets the state (blinking or not blinking) of the LED on the specied module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator privilege. To
enable the servers to blink or unblink, you must have the Server Administrator or the Debug Administrator
privilege.
Synopsis
racadm setled -m <module> -l <ledState>
Input
• -m <module> — Species the module whose LED you want to congure.
<module> can be one of the following:
– server–<n>, where n=1–16
– server–<nx>, where n=1–8; x = a, b, c, d (lower case)
– switch–<n>, where n=1–6
– cmc-active
– chassis
•
-l <ledState> — Species the LED state. The values are:
– 0 — No Blinking
72