Users Guide

Severity Message Cause
Critical All event logging is disabled. The Chassis/Enclosure cannot store events to the logs.
This usually indicates a problem with the control panel or
control panel cable.
Warning Log is full. Chassis has detected that only one more entry can be
added to the CEL (hardware log) before it is full.
Warning Log is almost full. Chassis event log is 75% full.
Table 49. Fan Status Screens
Severity Message Cause
Critical Fan <number> RPM is operating less than the lower
critical threshold.
The speed of the specified fan is not sufficient to provide
enough cooling to the system.
Critical Fan <number> RPM is operating greater than the
upper critical threshold.
The speed of the specified fan is too high, usually due to a
broken fan blade.
Table 50. IOM Status Screens
Severity Message Cause
Warning A fabric mismatch detected on I/O module <number>. The IO module fabric does not match that of the server or
the redundant I/O module.
Warning A link tuning failure detected on I/O module
<number>.
The IO module could not be set to correctly use the NIC on
one or more servers.
Critical A failure is detected on I/O module <number>. The I/O module has a fault. The same error can also
happen if the I/O module is thermal-tripped.
Table 51. iKVM Status Screen
Severity Message Cause
Warning Console is not available for Local KVM. Minor failure, such as corrupted firmware.
Critical Local KVM can not detect any hosts. USB host enumeration failure.
Critical OSCAR, on screen display is not functional for
the Local KVM.
OSCAR failure.
Non- Recoverable Local KVM is not functional, and is powered off. Serial RIP failure or USB host chip failure.
Table 52. PSU Status Screens
Severity Message Cause
Critical Power supply <number> failed. The PSU has failed.
Critical The power input for power supply <number> is lost. Loss of AC power or AC cord unplugged.
Warning Power supply <number> is operating at 110 volts, and
could cause a circuit breaker fault.
Power supply is plug into a 110 volt source.
Table 53. Server Status Screen
Severity Message Cause
Warning The system board ambient temperature is less than
the lower warning threshold.
Server temperature is getting cool.
Critical The system board ambient temperature is less than
the lower critical threshold.
Server temperature is getting cold.
229