Users Guide

Severity Message Cause
Warning The system board ambient temperature is greater
than the upper warning threshold.
Server temperature is getting warm.
Critical The system board ambient temperature is greater
than the upper critical threshold.
Server temperature is getting too hot.
Critical The system board Current Latch current is outside
of the allowable range
Current crossed a failing threshold.
Critical The system board battery failed. CMOS battery is not present or has no voltage.
Warning The storage battery is low. ROMB battery is low.
Critical The storage battery failed. CMOS battery is not present or has no voltage.
Critical The CPU <number> <voltage sensor name >
voltage is outside of the allowable range.
Critical The system board<voltage sensor name > voltage
is outside of the allowable range.
Critical The mezzanine card <number> <voltage sensor
name > voltage is outside of the allowable range.
Critical The storage <voltage sensor name > voltage is
outside of the allowable range.
Critical CPU <number> has an internal error (IERR). CPU failure.
Critical CPU <number> has a thermal trip (over-
temperature) event.
CPU overheated.
Critica CPU <number> configuration is unsupported. Incorrect processor type or in wrong location.
Critical CPU <number> is absent. Required CPU is missing or not present.
Critical Mezz B<slot number> Status: Add-in Card sensor
for Mezz B<slot number>, install error was
asserted.
Incorrect Mezzanine card installed for IO fabric.
Critical Mezz C<slot number> Status: Add-in Card sensor
for Mezz C<slot number>, install error was
asserted.
Incorrect Mezzanine card installed for IO fabric.
Critical Drive <number> is removed. Storage Drive was removed.
Critical Fault detected on Drive <number>. Storage Drive failed.
Critical The system board fail-safe voltage is outside of the
allowable range.
This event is generated when the system board voltages
are not at normal levels.
Critical The watchdog timer expired. The iDRAC watchdog timer expires and no action is set.
Critical The watchdog timer reset the system. The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to reboot.
Critical The watchdog timer powered off the system. The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to power off.
Critical The watchdog timer power cycled the system. The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
230