Viewing and Terminating CMC Sessions
You can view the number of users currently logged in to iDRAC and terminate the user sessions.
NOTE: To terminate a session, you must have Chassis Configuration Administrator privilege.
Viewing and Terminating CMC Sessions Using Web Interface
To view or terminate a session using Web interface:
1. In the system tree, go to Chassis Overview and click NetworkSessions.
The Sessions page displays the session ID, username, IP address, and session type. For more information about these
properties, see the CMC Online Help.
2. To terminate the session, click Terminate for a session.
Viewing and Terminating CMC Sessions Using RACADM
You must have administrator privileges to terminate CMC sessions using RACADM.
To view the current user sessions, use the getssninfo command.
To terminate a user session, use the closessn command.
For more information about these commands, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM
Command Line Reference Guide available at dell.com/support/manuals.
Configuring Enhanced Cooling Mode for Fans
The Enhanced Cooling Mode (ECM) feature provides additional cooling support using the third generation M1000e fans. The
Enhanced Cooling Mode (ECM) for fans is available only when all nine fan slots are populated with the new third generation M1000e
fans. The new third generation M1000e fans provide:
Superior cooling to the installed blades compared to previous M1000e fan generations, when the ECM feature is enabled.
Cooling equivalent to previous generations of M1000e fans at the same power, when the ECM feature is disabled.
ECM mode is recommended for:
Blade server configurations with high Thermal Design Power (TDP) processors.
Workloads where performance is a critical.
Systems deployed in environments where the inlet temperature exceeds 30°C [86°F].
,
NOTE: In the Enhanced Cooling Mode (ECM), the new generation fans provide superior cooling features when
compared to current generation fans of M1000e chassis. This increased cooling is not always needed and comes at the
expense of higher acoustics (where the system can sound up to 40% louder) and increased system fan power. You can
enable or disable the ECM feature on the basis of cooling required for a chassis.
By default, the ECM feature is disabled on a chassis. The ECM enabling and disabling operations are recorded in the CMC logs. The
ECM mode state is maintained after CMC failovers and chassis AC power cycles.
You can enable or disable the ECM feature using the CMC Web interface or the RACADM CLI interface.
Configuring Enhanced Cooling Mode for Fans Using Web Interface
To configure Enhanced Cooling Mode (ECM) for fans using CMC Web interface:
1. In the system tree, go to Chassis Overview, and then click FansSetup.