Users Guide

Connecting to Servers or I/O Modules Using Connect
Command
CMC can establish a connection to redirect the serial console of server or I/O modules.
For servers, serial console redirection can be accomplished using:
racadm connect command. For more information, see Chassis Management Controller for Dell PowerEdge M1000e RACADM
Command Line Reference Guide
at dell.com/support/manuals.
iDRAC Web interface serial console redirection feature.
iDRAC Serial Over LAN (SOL) functionality.
In a serial, Telnet, SSH console, the CMC supports the connect command to establish a serial connection to server or IOM modules. The
server serial console contains both the BIOS boot and setup screens, and the operating system serial console. For I/O modules, the switch
serial console is available.
CAUTION: When executed from the CMC serial console, the connect -b option stays connected until the CMC resets. This
connection is a potential security risk.
NOTE: The connect command provides the –b (binary) option. The –b option passes raw binary data, and
cfgSerialConsoleQuitKey is not used. Additionally, when connecting to a server using the CMC serial console, transitions
in the DTR signal (for example, if the serial cable is removed to connect a debugger) do not cause a logout.
NOTE: If an IOM does not support console redirection, the connect command displays an empty console. In that case, to
return to the CMC console, type the Escape sequence. The default console escape sequence is <CTRL><\>.
There are up to six IOMs on the managed system. To connect to an IOM:
connect switch-n
where n is an IOM label A1, A2, B1, B2, C1, and C2.
(See Figure 13-1 for an illustration of the placement of IOMs in the chassis.) When you reference the IOMs in the connect command, the
IOMs are mapped to switches as shown in the following table.
Table 35. : Mapping I/O Modules to Switches
I/O Module Label Switch
A1 switch-a1 or switch- 1
A2 switch-a2 or switch-2
B1 switch-b1 or switch-3
B2 switch-b2 or switch-4
C1 switch-c1 or switch-5
C2 switch-c2 or switch-6
NOTE: There can only be one IOM connection per chassis at a time.
NOTE: You cannot connect to pass-throughs from the serial console.
To connect to a managed server serial console, use the command connect server-<n><x>, where n is 1-8 and x is a,b, c, or d. You
can also use the racadm connect server-n command. When you connect to a server using the -b option, binary communication is
assumed and the escape character is disabled. If the iDRAC is not available, you see a
No route to host error message.
The connect server-n command enables the user to access the server's serial port. After this connection is established, the user can
view the server's console redirection through CMC's serial port that includes both the BIOS serial console and the operating system serial
console.