Users Guide

Managing I/O Fabric
The chassis can have up to six I/O modules (IOMs), where each IOM is a pass-through or switch module. The IOMs are classied into three
groups—A, B, and C. Each group has two slots—Slot 1 and Slot 2.
The slots are designated with letters, from left to right, across the back of the chassis: A1 | B1 | C1 | C2 | B2 | A2. Each server has slots for
two mezzanine cards (MCs) to connect to the IOMs. The MC and the corresponding IOM must have the same fabric.
Chassis IO is segregated into three discrete data paths: A, B and C. These paths are described as FABRICS and support Ethernet, Fibre
Channel, or InniBand. These discrete fabric paths are split into two IO Banks, bank one and bank two. Each server IO adapter (Mezzanine
Card or LOM) can have either two or four ports depending on the capability. These ports are divided evenly to IOM banks one and two to
allow for redundancy. When you deploy the Ethernet, iSCSI, or FibreChannel networks, span their redundant links across banks one and
two for maximum availability. The discrete IOM is identied with the fabric identier and the bank number.
Example: A1 denotes Fabric A in bank 1. C2 denotes Fabric Cin bank 2.
The chassis supports three fabric or protocol types. The IOMs and Mezzanine Cards in a group must have the same or compatible fabric
types.
Group A IOMS are always connected to the servers' on-board Ethernet adapters; the fabric type of Group A is always Ethernet.
For Group B, the IOM slots are permanently connected to the rst MC slot in each server module.
For Group C, the IOM slots are permanently connected to the second MC in each server module.
NOTE
: In the CMC CLI, IOMs are referred to by the convention, switch-n: A1=switch-1, A2=switch-2, B1=switch-3, B2=switch-4,
C1=switch-5, and C2= switch-6.
Topics:
Descripción general de la administración de redes Fabric
Conguraciones no válidas
Situación de encendido por primera vez
Supervisión de la condición del módulo de E/S
Viewing I/O Module Uplink and Downlink Status Using Web Interface
Viewing I/O Module FCoE Session Information Using Web Interface
Viewing Stacking Information for Dell PowerEdge M I/O Aggregator
Conguring Network Settings for IOM(s)
Restablecimiento de los módulos de E/S a la conguración predeterminada de fábrica
Actualización de software de módulo de E/S mediante la interfaz web del CMC
GUI del agregador de E/S (IOA GUI)
I/O Aggregator Module
Administración de VLAN para módulos de E/S
Administración de las operaciones de control de alimentación para módulos de E/S
Activación o desactivación del parpadeo del LED para los módulos de E/S
13
192 Managing I/O Fabric