Deployment Guide
■ Prerequisite
– Multiple appliances – Eight RJ45/Cat 5e or better cables for each appliance
• Fibre Channel with 10GbE appliance:
– Single appliance – Two LC optical ber cables or twinax cables (controllers are directly connected to each other; two
Twinax cables shipped with each appliance)
– Multiple appliances – Four LC optical ber cables or twinax cables for each appliance
• 10GbE iSCSI appliance – None (shared with SAN cables)
□ (10GbE optical networks only) Intel SFP+ transceivers purchased from Dell for use in an FS8600 appliance
• Fibre Channel with 10GbE appliance:
– Client network – Four Intel SFP+ transceivers for each appliance
– Internal network – Four Intel SFP+ transceivers for each appliance
• 10GbE iSCSI appliance:
– Client network – Four Intel SFP+ transceivers for each appliance
– SAN/internal network – Four Intel SFP+ transceivers for each appliance
NOTE: The FS8600 appliance is compatible with specic Intel SFP+ transceivers purchased only from Dell. Other
SFP+ transceiver models do not work in the FS8600 appliance.
Network Credentials
Make sure the following network credentials are available to complete the deployment successfully.
■
Prerequisite
□ (Fibre Channel only) Credentials to update Fibre Channel zoning
□ (Active Directory only) Site information and credentials to join the FluidFS cluster to Active Directory
Any of the following domain users can be used to join the cluster to Active Directory:
• Domain administrator account (preferred method)
• Domain account that has been delegated the join a computer to the domain privilege and full control over all
computer objects in the domain
•
Domain Organizational Unit (OU) administrator account that has been delegated the join a computer to the
domain privilege and full control over objects within that OU, including computer objects
– Before joining the FluidFS cluster to the domain, a computer object must be created by the OU administrator for the
FluidFS cluster.
– The FluidFS cluster computer object name and NetBIOS name must match.
– The FluidFS cluster computer object permissions must be congured to allow the OU administrator account to join it
to a domain.
□ (LDAP/NIS only) Site information and credentials to congure LDAP or NIS directory services for the FluidFS cluster
□ (Optional) Credentials to add DNS records for the FluidFS cluster
SAN and Internal Network for Fibre Channel Appliances
The following prerequisites apply to Fibre Channel with 1GbE appliances and Fibre Channel with 10GbE appliances.
Fibre Channel SAN Fabric
Make sure the Fibre Channel SAN fabric is ready for deployment.
6
Deployment Prerequisites