Release Notes

Table 17. Issues Fixed in Storage Manager 2018 R1.10
Issue Description
DSM-38641 Applying a snapshot prole to a volume that is the source of a replication might fail in Storage
Manager.
DSM-38565 The Storage Manager Server Agent might format Windows 2016 volumes using MBR instead of GPT.
DSM-37720 The Edit Data Collector Settings dialog box can be accessed from the Reports view by Storage
Manager users with Reporter privileges.
DSM-37188 The Do Not Expire option is not applied to snapshots created from the Snapshot Proles node.
DSM-27862 The Discover and Congure Storage Centers wizard congures the key management server for SEDs
but it does not manage the SEDs in a Secure Data folder.
Table 18. Issues Fixed in Storage Manager 2018 R1
Issue Description
DSM-32796 Storage Manager is reporting database errors once a day after installing an upgrade.
DSM-32600 The server.log les expand to greater than 1 GB in size and cause the C drive to be lled.
DSM-29430 When editing the advanced volume settings, conguring the Maximum Congured Volume Space to
more than the 500 terabyte limit of congured volume space per history may adversely aect failover
behavior.
DSM-29371 The Storage Manager trim stats operation is timing out due to a very large MS SQL database due to
retaining 365 days of data.
DSM-29001 Creating a server object for the local server might fail if the local server is running Windows Server
2016.
DSM-28683 Storage Manager displays an error after applying the High Priority Storage Prole to all volumes on an
ESXi server.
DSM-28481 In some cases, the Shut Down/Restart dialog box remains open after restarting a Storage Center
using Storage Manager.
DSM-27655 The Storage Manager Server Agent fails to format a volume on a server during a map and format
operation on servers running Windows Server 2016 and displays an error message. The volume is
successfully mapped to the server.
DSM-19752 Storage Center does not change the Data Progression Start Time if the time was changed by one hour
only.
DSM-17166 Storage Manager allows you to create a fault domain using the same target address and/or VLAN ID
as an existing fault domain.
DSM-16903 After removing and reinserting a controller on an SC7020 the ports are unbalanced but Storage
Manager does not immediately display the option to rebalance the ports.
DSM-14705 The Estimated Full Time for a volume might show an incorrect date of Jan 1, 1970 12:00:00 AM.
DSM-13534 The Class of Service Priority eld in the Fault Domain node might not match the iSCSI priority set on
the ports in the fault domain as seen when viewing the Data Center Bridging Information for that port.
DSM-10124 Storage Manager allows users to set preallocated storage on a new volume being mapped to a down
server. The operation fails.
DSM-9478 After a Copy/Mirror/Migrate schedule is complete, the schedule still appears in the client.
SCOS-45755 The volume space consumption limit cannot be set above 2 TB using Storage Manager.
SCOS-14951 After deleting volumes and snapshots, Storage Center does not immediately report the deleted volume
space as free space for a disk folder.
14 Storage Manager 2018 R1 Release Notes