Release Notes

Issue Description
Workaround: Monitor alerts using the Group Manager, opening the Alerts view in Unisphere or
opening the Events tab in Storage Manager.
DSM-23693 Storage Manager displays a PS Series group as inactive after a controller failover on the PS Series
group.
Workaround: Remove the PS Series group from Storage Manager then add it back.
DSM-17321 Storage Manager displays alerts and alarms for PS Series groups that have been cleared to the
recycling bin in Group Manager.
Workaround: Delete the alerts and alarms from the recycling bin in Group Manager.
DSM-13871 After performing an online Thin Import of a boot volume from a PS Series group to a Storage Center,
the server is unable to boot from the volume after mapping it to the server.
Workaround: Online Thin Import is not supported with boot volumes.
Open Issues Related to Replications and Live Volumes
The following are open issues are related to replications and Live Volumes:
Issue Description
DSM-28520 After performing a test activate disaster recovery, Storage Manager does not allow you to delete that
volume from the Replications and Live Volumes tab.
Workaround: Unmap then delete the volume from the Storage view.
DSM-15338 Disaster recovery activation fails if the Snapshot Prole assigned to the restore point has been deleted.
Workaround: Edit the restore point to remove the Snapshot Prole.
DSM-9294 When creating multiple replications or Live Volumes simultaneously, correcting a conguration error
and resuming the process can create duplicate replications or Live Volumes.
Workaround: If a creation operation fails, do not use the wizard to correct the conguration error and
continue. Instead, exit and restart the wizard, then resume creating replications or Live Volumes from
the point of failure.
SCOS-12067 When importing a volume, Storage Manager does not allow you to select 0 as the LUN number.
Workaround: None
Open Issues Related to Dell Storage Replication Adapter (SRA)
The following open issues are related to Dell Storage Replication Adapter (SRA):
Table 30.
Issue Description
DSM-39992
The following error message is displayed during the Synchronize Storage step of the Dell SRA
workow for all versions of SRM:
Warning - Internal error: std::exception 'class
Dr::Xml::XmlValidateException' "No character data is allowed by content
model"
Storage Manager 2018 R1 Release Notes 21